6000W ep 3000 pro series hf inverter
Low frequency pure sine wave combined inverter&A/C charger EP3000 PRO Series 6 kw; Quiet,high efficiency operation front panel LED+LCD indicators and adjustable switch selectors selectable settings for flooded lead acid,Gel,or absorbed glass mat(AGM) batteries. Mainly for home and office applicances such as TV, refrigerator, fans lights and computers etc.
Features:
- Pure sine wave output
- Max 140A automatic 3-stage battery charger
- Charger current is Adjustable (0-100%)
- Automatically send signal to start generator
- Supporting USB communication and BTS & AGS port
- Battery/AC priority
6000W ep 3000 pro series hf inverter Specifications
MODEL EP30-6KW
Nominal Battery System Voltage 48VDC
INVERTER OUTPUT
Continuous output power           6.0KW
Surge rating       24000VA
Capable Of Starting Electric Motor           4HP
Output waveform           Pure sine wave / same as input (bypass mode)
Inverter Efficiency(Peak) >88%
Line mode efficiency      >95%
Power factor      1.0
Nominal output voltage RMS      220V / 230V / 240VAC ±10% (RMS)
Output frequency           50Hz
Short circuit protection Yes (1sec after fault)
Typical transfer time       10ms(max)
AC INPUT
Voltage 90-280VAC
Selectable Voltage Range             170-280VAC(For Personal Computers)
Frequency Range             50Hz / 60Hz
BATTERY
Minimum start voltage  40.0V±0.6 / 42.0V±0.6
Low battery alarm           42-50VDC
Low battery Cutoff          40.0V±0.6 / 42.0V±0.6
High voltage alarm          60VDC
High battery voltage recover       57VDC
Idle consumption-search mode <60W when power saver on
CHARGER
Output voltage Depends on battery type
Charger AC input breaker rating 80A
Max charge power rate 1/3 Rating power
Overcharge protection S.D.         62.8VDC
Maximum Charge Current            100A
BTS
Temperature rate @25°C             4mv charging voltage descent, per 1℃ rise
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal voltage              220V / 230V / 240VAC
Max input AC voltage     300VAC for 230VAC HV mode
Nominal input frequency             50Hz or 60Hz
Overload protection (SMPS load)Â Â Â Â Â Â Â Â Â Â Â Â Â Â Circuit breaker
Output short circuit protection  Circuit breaker
Bypass breaker rating    63A
Max bypass current        63Amp
MECHANICAL SPECIFICATIONS
Mounting           Wall mount
Inverter dimensions (W*H*D) (mm)Â Â Â Â Â Â Â Â 670*410*215
Inverter weight (solar chg) (kg)Â Â 67.5
Shipping dimensions (W*H*D) (mm)Â Â Â Â Â Â 802*533*429.5
Shipping weight (solar chg) (kg) 87
OTHER
Operation Temperature Range   0℃ to 40℃
Storage Temperature     -15℃ to 60℃
Audible Noise   60bB MAX
Display LED+LCD